Uni-T Brand Digital Megger Meter Insulation Tester, Model: UT501
This UNI-T UT501 insulation tester measures resistance, insulation resistance, and AC/DC voltage.
Download UNI-T UT501 Insulation tester user manual
- Functions:
- insulation resistance
- resistance
- DC voltage
- AC voltage
- Auto-ranging
- Alarm light display and buzzer
- Low battery indication
UNI-T UT501 Insulation Tester Technical Specifications
Display | LCD with backlight, 70.6 × 34 mm |
Output voltage | Range | 250 V / 500 V / 1000 V |
Accuracy | ±10% |
Current | Range | 250 V | 1 mA |
500 V |
1000 V |
Accuracy | ±10% |
Short circuit current | <2 mA |
Insulation resistance measurement | Range | 250 V | 3 MΩ to 2000 MΩ |
500 V |
1000 V | 3 MΩ to 2 GΩ |
Accuracy | ±3% 5 |
Voltage measurement | 1000 V DC, 750 V AC |
Accuracy | ±2% 3 |
Power | 6 × 1.5 V battery (R14) |
Dimensions (H × W × D), mm | 150 × 100 × 71 |
Weight, kg | 0.5 |
UNI-T UT501 Insulation Tester Package
- Megohmmeter UNI-T UT501 — 1 pc.
- Test leads — 1 set
- Test probes — 1 set
- Alligator clip — 1 pc.
- Carrying bag — 1 pc.
- Strap — 1 pc.
- 1.5 V battery (LR14) — 6 pcs.
- User manual — 1 pc.
If you'd like to know more about this chemical or need any analysis
report regarding this chemical then contact us support@echem.com.bd.
Uni-T Digital Megger Meter Insulation Tester UT501:
- Digital Display: Clear digital display for easy reading of results.
- Insulation Resistance Measurement: Measures insulation resistance up to 1000V DC with a wide range.
- Test Voltage Selection: Offers selectable test voltages of 250V, 500V, and 1000V for various insulation testing needs.
- Resistance Measurement: Measures resistance up to 20MΩ with high accuracy.
- Auto Discharge Function: Automatically discharges the residual voltage after testing to ensure safety.
- Data Hold Function: Holds the measured data for convenient reading and recording.
- Backlight Display: Built-in backlight for visibility in low-light conditions.
- Auto Power Off: Automatically powers off to conserve battery life when idle.
- Safety Standards: Complies with safety standards like IEC/EN 61010-1, CAT III 1000V.