Analog Oscilloscope LODESTAR MOS-620CH
Place of Origin:
|
China
|
Brand Name:
|
LODESTAR
|
Model Number:
|
620CH
|
Bandwidth:
|
20MHz
|
Type:
|
Analog Oscilloscope
|
Channels:
|
2
|
Specifications
- Build-in 6 Digit Frequency Counter
- 20MHz/40MHz/50MHz Dual Channel
- 10 times sweep magnification
- TV Synchronization, X-Y mod
Horizontal System
- Sweep time: 0.2uSec~0.5Sec/DIV,20steps in 1-2-5 sequence;
- Sweep time accuracy:±3%
- Vernier sweep time control:≤1/2.5 of panel-indicated and
#118alue;
- Sweep magnification: 10 times;
- ×10MAG sweep time accuracy: ±5% (20nSec~50nSec are
uncalibrated);
- Linearity:±5%,×10MAG: ±10% (0.2s~1us)
- Position shift caused by ×10MAG: within 2DIV. At CRT screen
center
X-Y MODE:
- Frequency bandwidth: DC to at least 500KHz;
- X-Y phase difference:≤3°at DC~50KHz
- Sensitivity: Same as the vertical axis. (X-axis: CH1 input
signal; Y-axis: CH2 input signal.);
- CALIBRATION VOLTAGE
- Waveform: Positive-going square wave;
- Frequency: Approx. 1KHz;
- Duty ratio: Within 48:52;
- Output voltage: 2Vp-p±2%;
- Output impedance: Approx.1KΩ
CALIBRATION SIGNAL
- Waveform: Positive-going square wave;
- Frequency: Approx. 1KHz;
- Duty ratio: Within 48:52;
- Output voltage: 2Vp-p±2%;
- Output impedance: Approx.1KΩ
- Type: 6-inch rectangular type, internal graticule;
- Phosphor:P31;
- Acceleration voltage: Approx.2KV(20MHz)/Approx.12kv(40MHz);
- Effective screen size:8×10DIV[1DIV=10mm(0.39in)];
- Graticule: Internal;
- Trace rotation: Provided
Uses of LODESATAR MOS-620CH Analog Oscilloscope:
Signal Observation:
- The primary use of this oscilloscope is to observe and analyze electrical signals. It can display the waveform of voltage signals, allowing users to see the shape, amplitude, frequency, and timing of the signal.
Troubleshooting Circuits:
- It is used to diagnose and troubleshoot issues in electronic circuits by visualizing the signals at various points in the circuit. This helps identify problems like signal distortion, noise, or improper functioning of components.
Measuring Signal Parameters:
- The oscilloscope can measure key signal parameters, such as peak-to-peak voltage, frequency, and phase differences between signals. These measurements are crucial in designing and testing electronic circuits.
Component Testing:
- The dual-channel feature allows the comparison of two signals simultaneously, which is useful for testing and comparing the performance of components like transistors, capacitors, and other active and passive components.
Timing Analysis:
- The device can be used to measure and analyze the timing relationships between different signals, which is essential in digital circuits and communication systems where timing is critical.
Waveform Comparison:
- The dual-channel capability of the MOS-620CH allows users to compare two different waveforms in real-time. This is particularly useful in applications where matching signals or verifying synchronization between signals is necessary.
If you'd like to know more about this chemical or need any analysis report regarding this chemical then contact us: support@echem.com.bd.
Analog Oscilloscope LODESTAR MOS-620CH
- High luminance, internal graticule CRT
- Japanese electronic encoder, light, handy and reliable
- Fully sealed long live vertical mode switch
- ALT Triggering Function. Two independent signals
- simultaneous observation
- Build-in 6 Digit Frequency Counter
- 20MHz/40MHz/50MHz Dual Channel
- 10 times sweep magnification
- TV Synchronization-Y mode
WARNING:
- Before plugging into AC mains,carefully t set the swaitch
according to the ac input voltage.
- Do not use this power supply nesr water.
- Don not operate or touch this power supply with wet hands.
- Don not pen the casing of the power supply when it is
connected to ac mains.
CAUTION:
- USE a grounded 3 pin AC source.
- This unit is for indoor use only.
- Do not operate or place this unit in a humid,dusty ,in
direct sunlight location or near any heat source.
- Do not block any ventilation openings of the unit.
- This unit must be used within the specified rating, regular
excessive continuous loading amy cause damage to the power supply.